E380 EIM interlock relay fault

High severity

What the control is telling you

EIM interlock relay energized but its input not sensed after three seconds (furnace or air handler modes); no heating or cooling. S30/S40 thermostat alert code 380 (shown as E380 on the unit control display).

Applies to: Lennox communicating air handlers and EIM-equipped indoor units in S30/S40 smart thermostat systems

Likely causes

  • Failed interlock relay on the EIM
  • Wiring fault

Test and repair steps

  1. Check EIM interlock wiring.
  2. The EIM drops the relay, waits five minutes, and tries again if the call is still there.
  3. Replace the EIM if the relay fails.
  4. Clears after the fault recovers.

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.28. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.