Lennox · Air handler

E292 Blower motor start fault

High severity

What the control is telling you

The indoor blower motor will not start; the system goes into Watchguard mode. S30/S40 thermostat alert code 292 (shown as E292 on the unit control display).

Applies to: Lennox communicating air handlers and EIM-equipped indoor units in S30/S40 smart thermostat systems

Likely causes

  • Seized bearing
  • Stuck or obstructed blower wheel
  • Failed motor or motor module

Test and repair steps

  1. Warning: Disconnect power before handling the blower.
  2. Check the wheel turns freely and remove obstructions.
  3. Replace the motor, motor module or wheel if it does not run or meet performance standards.
  4. Refer to Lennox note H-17-02, which covers all communicating variable speed motors.
  5. Clears after the blower starts successfully.

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.24. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.