Weil-McLain · Boiler · Startup
Express Setup Example B wizard order (Combi with two zones)
What happens, in order
- Choose SINGLE BOILER and press the right arrow.
- Accept the anti-scald valve confirmation, or disable DHW if none is installed.
- Verify the boiler model, sensor status and fuel type, altitude, units, WWSD temp and high temp limit.
- Set date and time, then press the right arrow.
- Press USE WIZARD.
- Set Combi enabled, hot water temp, max on time, preheat and eco boost.
- Set Input/Output 2 to heat demand, priority 2, system type and target settings.
- Set Input/Output 3 to heat demand, priority 3, system type and target settings.
- Finish the wizard and enter time, date and maintenance information when prompted.
Timings and thresholds
| Item | Value |
|---|---|
| Hot water temp (Combi) | 120°F default example, up to 140°F |
| Combi max on time | 60 minutes |
| Zone max on time | 30 minutes |
| Zone min on time | 15 minutes |
| Target boost time | OFF |
Applies to: ECO Tec Series 3 Combi with two zones
Models
ECO TEC 110 COMBI
More Weil-McLain boiler sequences
- Annual start-up checklist (service technician) · Startup
- Blower calibration at first startup · Startup
- Check flame and combustion with instruments · Startup
- Check flame and combustion with instruments at high fire, low fire and auto · Startup
- Closure switch interlock startup sequence · Startup
- Final verification checklist at commissioning · Startup
- Lighting and operating sequence · Startup
- Power-up and ignition sequence · Startup
Take it to the job
Sequences of operation, error codes and tips work offline in the HVACopedia app.
Source: ECO Tec Series 3 boiler manual, p. 100-104. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.