Weil-McLain · Boiler · Startup
Annual start-up checklist (service technician)
What happens, in order
- Address reported problems and inspect the boiler area.
- Inspect the boiler interior and jacket door gaskets; clean the condensate trap.
- Check all piping for leaks and check air openings.
- Inspect vent system, air piping and water system, expansion tank(s) and ignition electrode.
- Check ignition wiring and all boiler wiring.
- Check control settings and low water cutoff.
- Perform start-up and checks.
- Check burner flame, flame signal and blower speeds.
- Check flue gas temperature and run manual test mode.
- Check inlet gas pressure and internal circulation pump.
- Check the relief valve, review with owner, and reinstall jacket door.
Codes you may see during this
Ignition Fault 1
Applies to: ECO Tec Series 3 gas boilers
Models
80110150199
More Weil-McLain boiler sequences
- Blower calibration at first startup · Startup
- Check flame and combustion with instruments · Startup
- Check flame and combustion with instruments at high fire, low fire and auto · Startup
- Closure switch interlock startup sequence · Startup
- Express Setup Example B wizard order (Combi with two zones) · Startup
- Final verification checklist at commissioning · Startup
- Lighting and operating sequence · Startup
- Power-up and ignition sequence · Startup
Take it to the job
Sequences of operation, error codes and tips work offline in the HVACopedia app.
Source: ECO Tec series 3 boiler manual, p. 138-144. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.