Weil-McLain · Boiler · Freeze protection
Circulator freeze protection
What happens, in order
- Sensor reads below the on threshold.
- Control energizes the circulator.
- Circulator stays on until the sensor rises above the off threshold.
- Control de-energizes the circulator.
- A call for heat during this time proceeds normally.
Timings and thresholds
| Item | Value |
|---|---|
| Circulator on when sensor below | 40°F |
| Circulator off when sensor above | 45°F |
Applies to: CGi Series 5 with Freeze Protect enabled
More Weil-McLain boiler sequences
- Annual start-up checklist (service technician) · Startup
- Blower calibration at first startup · Startup
- Check flame and combustion with instruments · Startup
- Check flame and combustion with instruments at high fire, low fire and auto · Startup
- Closure switch (flow switch or CAD) proof sequence · Startup
- Closure switch interlock startup sequence · Startup
- Express Setup Example B wizard order (Combi with two zones) · Startup
- Final verification checklist · Startup
Take it to the job
Sequences of operation, error codes and tips work offline in the HVACopedia app.
Source: Weil-McLain CGi Series 5 boiler manual, p. 54. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.