Therm-Control low-temperature protection during start-up

Vitorond 200 VD2A

What happens, in order

  1. Phase 1 The Therm-Control sensor has not reached its setpoint. The control shuts off the system pump, closes the mixing valve if fitted, and drives the burner to full fire.
  2. Phase 2 When the Therm-Control sensor exceeds its setpoint, the mixing valve opens and flow through the boiler increases (50% in the example).
  3. Phase 3 As return temperature rises, the mixing valve opens fully to 100% flow. The control then modulates the burner to meet the setpoint.

Applies to: Vitorond 200 VD2A with Vitotronic control

Models

VD2A-125VD2A-160VD2A-195VD2A-230VD2A-270

More Viessmann boiler sequences

Take it to the job

Sequences of operation, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitorond 200 VD2A installation instructions, p. 10. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.