Viessmann · Boiler · Startup
Starting up the boiler (single boiler or boiler within a multi-boiler system)
What happens, in order
- Check the heating system pressure on the manometer. If the needle is below the red marker, the pressure is too low: add water or call the heating contractor.
- Open the gas shut-off valve (or the oil pipe shut-off valves at the boiler, whichever applies).
- Switch on the power supply, for example at the separate fuse or disconnect switch.
- Switch on the heating system on/off switch (item 8). The green operating status lamp lights and, after a short time, the boiler temperature shows in the display.
- The boiler is now ready for operation.
Applies to: Vitotronic 100, GC1 control unit; in a multi-boiler system only the Vitotronic 100 and its own boiler start up
More Viessmann boiler sequences
- AUX output as combustion air function · Startup
- Boiler startup protection · Startup
- Commissioning assistant at first start-up · Startup
- Control commissioning start-up · Startup
- Initial start-up preparation · Startup
- Initial start-up sequence after installation · Startup
- Lighting and operating instructions · Startup
- Matching the control unit to a modulating burner · Startup
Take it to the job
Sequences of operation, error codes and tips work offline in the HVACopedia app.
Source: Viessmann Vitotronic 100 GC1 operating instructions, p. 7. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.