Trane · Heat pump · Heating

Heat pump warm air discharge

XR402

What happens, in order

  1. With BK output enabled and installer step 15 on, each heat pump heating stage reduces indoor airflow.
  2. The lower airflow gives warmer discharge air from the registers.

Timings and thresholds

ItemValue
Indoor airflow per heating compressor stage77%

Applies to: Heat pump with variable speed indoor unit and BK output

More Trane heat pump sequences

Take it to the job

Sequences of operation, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane XR402 installer's guide 18-HD29D3-4, p. 15. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.