Trane · Heat pump · Heating

Heat pump low-temperature fallback to aux

XR302XR303

What happens, in order

  1. If indoor temperature drops below 45°F from a heat pump fault, the heat pump turns off and aux heat is used.
  2. 'Call for Service' shows on the display.
  3. Press any key to retry the heat pump and clear the call-for-service icon.
  4. Or when setpoint is reached on aux, the heat pump resumes on the next call for heat.

Codes you may see during this

Call for Service

Applies to: HP1/HP2 with aux heat

Models

TCONT302TCONT303

More Trane heat pump sequences

Take it to the job

Sequences of operation, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane XR302/XR303 installation and user guide, p. 18. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.