Mitsubishi heat pump error codes
34 codes (17 faults, 17 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| E0 | Remote controller not receiving from indoor unit | Medium |
| E1 | Remote controller memory error | Low |
| E2 | Remote controller clock error | Low |
| E3 | Remote controller cannot transmit | Medium |
| E4 | Indoor unit not receiving from remote controller | Medium |
| E5 | Indoor unit cannot transmit to remote controller | Medium |
| E6 | Indoor/outdoor communication - indoor not receiving | High |
| E7 | Indoor unit transmit error to outdoor unit | High |
| LED1 (indoor board) | Indoor board LED1 - control power | Normal status |
| LED2 (indoor board) | Indoor board LED2 - remote controller power | Normal status |
| LED3 (indoor board) | Indoor board LED3 - indoor/outdoor communication | Normal status |
| P1 | Room (intake) air sensor TH1 open or shorted | Medium |
| P2 | Liquid pipe sensor TH2 open or shorted | Medium |
| P4 | Drain float switch disconnected | Medium |
| P5 | Drain overflow - float switch wet with pump running | High |
| P6 | Coil freeze or overheat protection | High |
| P8 | Pipe temperature out of range (coil not cooling or heating) | High |
| P9 | Coil sensor TH5 open or shorted | Medium |
| Centrally Controlled indicator | Operation prohibited by master controller | Normal status |
| FILTER | Clean the filter indicator | Normal status |
| Fb | Indoor control board memory error | High |
| Locked indicator | Remote buttons locked | Normal status |
| Louver display | Swing louver action indicator | Normal status |
| NOT AVAILABLE | Remote message - function not available | Normal status |
| PA | Water leak detected | High |
| PLEASE WAIT | Remote controller start-up message | Normal status |
| Power On indicator | Power on indicator | Normal status |
| Room temperature blinking | Room temperature out of display range | Normal status |
| Self-check (wired remote) | Remote controller self-check mode | Menu / mode display |
| Self-check beeps (wireless remote) | Wireless remote self-check feedback | Normal status |
| Sensor indication | Remote's own temperature sensor in use | Normal status |
| TEST RUN (wireless remote) | Wireless remote test run | Menu / mode display |
| Timer indicators | Timer set indicators | Normal status |
| Ventilation indicator | Ventilation mode running | Normal status |
Models covered
PEAD-RP100JAPEAD-RP100JALPEAD-RP125JAPEAD-RP125JALPEAD-RP140JAPEAD-RP140JALPEAD-RP35JAPEAD-RP35JALPEAD-RP50JAPEAD-RP50JALPEAD-RP60JAPEAD-RP60JALPEAD-RP71JAPEAD-RP71JAL
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.