Mitsubishi heat pump error codes

34 codes (17 faults, 17 normal display and menu codes).

CodeMeaningSeverity / type
E0Remote controller not receiving from indoor unitMedium
E1Remote controller memory errorLow
E2Remote controller clock errorLow
E3Remote controller cannot transmitMedium
E4Indoor unit not receiving from remote controllerMedium
E5Indoor unit cannot transmit to remote controllerMedium
E6Indoor/outdoor communication - indoor not receivingHigh
E7Indoor unit transmit error to outdoor unitHigh
LED1 (indoor board)Indoor board LED1 - control powerNormal status
LED2 (indoor board)Indoor board LED2 - remote controller powerNormal status
LED3 (indoor board)Indoor board LED3 - indoor/outdoor communicationNormal status
P1Room (intake) air sensor TH1 open or shortedMedium
P2Liquid pipe sensor TH2 open or shortedMedium
P4Drain float switch disconnectedMedium
P5Drain overflow - float switch wet with pump runningHigh
P6Coil freeze or overheat protectionHigh
P8Pipe temperature out of range (coil not cooling or heating)High
P9Coil sensor TH5 open or shortedMedium
Centrally Controlled indicatorOperation prohibited by master controllerNormal status
FILTERClean the filter indicatorNormal status
FbIndoor control board memory errorHigh
Locked indicatorRemote buttons lockedNormal status
Louver displaySwing louver action indicatorNormal status
NOT AVAILABLERemote message - function not availableNormal status
PAWater leak detectedHigh
PLEASE WAITRemote controller start-up messageNormal status
Power On indicatorPower on indicatorNormal status
Room temperature blinkingRoom temperature out of display rangeNormal status
Self-check (wired remote)Remote controller self-check modeMenu / mode display
Self-check beeps (wireless remote)Wireless remote self-check feedbackNormal status
Sensor indicationRemote's own temperature sensor in useNormal status
TEST RUN (wireless remote)Wireless remote test runMenu / mode display
Timer indicatorsTimer set indicatorsNormal status
Ventilation indicatorVentilation mode runningNormal status

Models covered

PEAD-RP100JAPEAD-RP100JALPEAD-RP125JAPEAD-RP125JALPEAD-RP140JAPEAD-RP140JALPEAD-RP35JAPEAD-RP35JALPEAD-RP50JAPEAD-RP50JALPEAD-RP60JAPEAD-RP60JALPEAD-RP71JAPEAD-RP71JAL

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.