Mitsubishi · Heat pump
Self-check beeps (wireless remote) Wireless remote self-check feedback
What the display is showing
During self-check with the wireless remote, the indoor unit gives two beeps to confirm the start signal was received. If no further beeps come and the OPERATION INDICATOR lamp does not light, no errors are stored. Three beeps in a row (0.4 s each) after the first two mean the refrigerant address entered is wrong. Real errors show as a beep/lamp flash count.
Applies to: Mr. Slim PEAD-RP JA(L) ducted indoor units with PAR-21MAA wired remote
Models that show this code
14 models in Mr. Slim PEAD-RP JA(L) ducted indoor unit
Other codes on the same units
- PLEASE WAIT Remote controller start-up message
- Power On indicator Power on indicator
- Room temperature blinking Room temperature out of display range
- Self-check (wired remote) Remote controller self-check mode
- Sensor indication Remote's own temperature sensor in use
- TEST RUN (wireless remote) Wireless remote test run
- Timer indicators Timer set indicators
- Ventilation indicator Ventilation mode running
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Mitsubishi PEAD-RP35JA(L) Service Manual, 10-2 Self-Check Function, output patterns A and B, p.29. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.