Midea mini-split error codes

127 codes (94 faults, 33 normal display and menu codes).

CodeMeaningSeverity / type
d1Demand response signal DR1 receivedNormal status
d2Demand response signal DR2 receivedNormal status
d3Demand response signal DR3 receivedNormal status
E1Indoor / outdoor communication errorHigh
EC07Outdoor fan speed out of rangeHigh
EC50Outdoor temperature sensor faultMedium
EC51Outdoor EEPROM errorHigh
EC52Condenser coil sensor (T3) faultMedium
EC53Outdoor ambient sensor (T4) faultMedium
EC54Discharge temperature sensor (TP/T5) faultMedium
EC55IPM temperature sensor faultMedium
EC56Indoor coil outlet sensor (T2B) faultMedium
EC57Refrigerant pipe sensor faultMedium
EC71Outdoor fan motor over-currentHigh
EC72Outdoor fan motor phase lossHigh
EH00Indoor EEPROM errorHigh
EH0AIndoor EEPROM errorHigh
EH0bIndoor PCB to display board communication errorMedium
EH02Zero-crossing signal errorMedium
EH03Indoor fan speed out of rangeHigh
EH30Indoor external fan low voltageMedium
EH31Indoor external fan over voltageMedium
Eh60Room sensor (T1) faultMedium
Eh61Indoor coil sensor (T2) faultMedium
EL0CRefrigerant leak detectedHigh
EL01Indoor / outdoor communication errorHigh
F0Current overload protectionHigh
F1Outdoor ambient sensor (T4) faultMedium
F2Condenser coil sensor (T3) faultMedium
F3Discharge sensor (T5) faultMedium
F4Outdoor EEPROM errorHigh
F5Outdoor fan speed out of controlHigh
FL14Indoor and outdoor units not compatibleMedium
J0Outdoor coil overheat in coolingMedium
J1Indoor coil temperature protection in heatingMedium
J2Discharge temperature protectionHigh
J3PFC module protectionHigh
J4Main board to IPM board communication errorHigh
J5High pressure protectionHigh
J6Low pressure protectionHigh
J8AC voltage protectionHigh
LC01Speed limited by condenser temperatureMenu / mode display
LC02Speed limited by discharge temperatureMenu / mode display
LC03Speed limited by currentMenu / mode display
LC05Speed limited by voltageMenu / mode display
LC06IPM high temperature / PFC frequency limitMedium
LH00Speed limited by indoor coil temperatureMenu / mode display
LH07Speed limited by remoteMenu / mode display
P0Inverter module (IPM) faultCritical
P1Over or under voltage protectionHigh
P2Compressor top overheat (OLP)High
P3Low outdoor temperature cut-off in heatingLow
P4Compressor drive faultHigh
P7IPM temperature sensor faultMedium
PC00Inverter module (IPM) protectionCritical
PC0ACondenser high temperature protectionMedium
PC0FPFC module protectionHigh
PC0LOutdoor temperature too lowLow
PC02Compressor top overheat (OLP)High
PC03Pressure protectionHigh
PC04Inverter compressor drive errorHigh
PC06Discharge temperature protectionHigh
PC08Outdoor over-current protectionHigh
PC10Low AC supply voltageHigh
PC11AC supply voltage protection (over voltage)High
PC12DC bus high voltage / 341 MCE errorHigh
PC30High pressure protectionHigh
PC31Low pressure protectionHigh
PC40Main chip to compressor drive chip communication errorHigh
PC41Current input detection protectionMedium
PC42Compressor start failureHigh
PC43Compressor phase lossHigh
PC44Zero speed protectionHigh
PC45Compressor drive chip (IR / 341 PWM) failureHigh
PC46Compressor speed out of controlHigh
PC49Compressor over-currentHigh
PCA1Refrigerant pipe condensation protectionLow
PH09Anti-cold-air in heatingNormal status
PH90Evaporator coil too hotMedium
PH91Evaporator coil too coldMedium
--Indoor units mode conflictMenu / mode display
APWi-Fi pairing (AP mode)Menu / mode display
CLFilter cleaning reminder / Active CleanMenu / mode display
CPRemote switched offMenu / mode display
E-C-OECO modeNormal status
FCForced coolingNormal status
FH 0dFault - see outdoor unitMenu / mode display
FPLow-temperature heating (8 C mode)Normal status
FbVapor injection inlet sensor faultMedium
FdVapor injection outlet sensor faultMedium
LLControls lockedMenu / mode display
ODU --Outdoor board standbyNormal status
ODU CEAutomatic wiring / piping check runningMenu / mode display
ODU E0Outdoor EEPROM error (outdoor board)High
ODU E2Indoor / outdoor communication error (outdoor board)High
ODU E3IPM to main board communication error (outdoor board)High
ODU E4Outdoor or T2B sensor fault (outdoor board)Medium
ODU E5Over or under voltage (outdoor board)High
ODU E6PFC module protection (outdoor board)High
ODU E8Outdoor fan speed fault (outdoor board)High
ODU EdAdapter / inverter board to main board communication errorHigh
ODU F1Zone A coil outlet sensor (T2B-A) faultMedium
ODU F2Zone B coil outlet sensor (T2B-B) faultMedium
ODU F3Zone C coil outlet sensor (T2B-C) faultMedium
ODU F4Zone D coil outlet sensor (T2B-D) faultMedium
ODU F5Zone E coil outlet sensor (T2B-E) faultMedium
ODU F6Zone F coil outlet sensor (T2B-F) faultMedium
ODU Hz readoutCompressor running frequencyNormal status
ODU LCLow ambient cooling modeNormal status
ODU LPLow outdoor temperature protection (outdoor board)Low
ODU P0Compressor top overheat (outdoor board)High
ODU P1High pressure protection (outdoor board)High
ODU P2Low pressure protection (outdoor board)High
ODU P3Current overload (outdoor board)High
ODU P4Discharge temperature protection (outdoor board)High
ODU P5Condenser high temperature (outdoor board)Medium
ODU P6Inverter module (IPM) fault (outdoor board)Critical
ODU PHCompressor pre-heatNormal status
ODU ROOil return cycleNormal status
OffTimer offMenu / mode display
OnTimer onMenu / mode display
SCSelf clean runningNormal status
SDPower abnormal detectionMenu / mode display
dEDemand response input errorMenu / mode display
dFDefrostNormal status
nANo faultNormal status
nFFilter replacement reminderMenu / mode display

Models covered

DLCMHBH24CAKDLCMHBH30DAKDLCMHBH36DAKDLCMHBH48EAKDLCMRBH18BAKDLCMRBH36DAKDLCMRBH48EAKDLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.