Midea · Mini-split
EH00 Indoor EEPROM error
What the control is telling you
The indoor main chip gets no answer from its EEPROM chip. Also shown as EH0A.
Applies to: DLFSHBH high wall indoor units 09-24K (Midea / Carrier / Viessmann) on DLC multi-zone or single-zone outdoor units
Likely causes
- Bad indoor PCB
Test and repair steps
- Safety kill power at the disconnect and wait for the inverter capacitors to discharge before touching boards or wiring.
- Power off 2 minutes and restart.
- If it comes back, replace the indoor main PCB.
Models that show this code
5 models in Midea DLFSHBH wall indoor (DLCM multi-zone)
Other codes on the same units
- EC54 Discharge temperature sensor (TP/T5) fault
- EC56 Indoor coil outlet sensor (T2B) fault
- EH0A Indoor EEPROM error
- EH0b Indoor PCB to display board communication error
- EH02 Zero-crossing signal error
- EH03 Indoor fan speed out of range
- EH30 Indoor external fan low voltage
- EH31 Indoor external fan over voltage
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17, p.25. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.