Rinnai · Boiler · Freeze protection

Freeze protection operation

I-Series Plus

What happens, in order

  1. Boiler detects low outdoor ambient temperature and starts freeze protection.
  2. Protection works down to -22 F (-30 C) outdoor temperature.
  3. Pump may circulate water and/or boiler may fire to keep the boiler from freezing.
  4. Power and gas must be supplied for freeze protection to work.
  5. Pressure and supply temperature alternate on the controller display.
  6. The CH and DHW icons may alternate during the sequence.
  7. Internal freeze protection does not guarantee the system piping will not freeze.

Applies to: All I-Series Plus condensing combi boilers

More Rinnai boiler sequences

Take it to the job

Sequences of operation, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Rinnai I-Series Plus Condensing Combi Boiler Manual, p. 118. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.