Rinnai · Boiler · Freeze protection
Freeze protection operation
What happens, in order
- Boiler detects low outdoor ambient temperature and starts freeze protection.
- Protection works down to -22 F (-30 C) outdoor temperature.
- Pump may circulate water and/or boiler may fire to keep the boiler from freezing.
- Power and gas must be supplied for freeze protection to work.
- Pressure and supply temperature alternate on the controller display.
- The CH and DHW icons may alternate during the sequence.
- Internal freeze protection does not guarantee the system piping will not freeze.
Applies to: All I-Series Plus condensing combi boilers
More Rinnai boiler sequences
- Fill and deaerate the boiler during commissioning · Startup
- First-time settings from the boiler controller · Startup
- Normal ignition sequence · Startup
- DHW recirculation on a dedicated return line (flow check) · Domestic hot water
- DHW recirculation pump run logic (dedicated return mode) · Domestic hot water
- DHW recirculation with crossover valve and thermal bypass · Domestic hot water
- DHW run limit and heating restart · Domestic hot water
- Automated descaling flush sequence · Pump/purge
Related
Rinnai error codes · Rinnai tips · Rinnai parts · All Rinnai sequences
Take it to the job
Sequences of operation, error codes and tips work offline in the HVACopedia app.
Source: Rinnai I-Series Plus Condensing Combi Boiler Manual, p. 118. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.