Rinnai · Boiler · Domestic hot water

DHW recirculation with crossover valve and thermal bypass

I-Series Plus

What happens, in order

  1. Use the crossover mode plumbing with a thermal bypass valve installed at the furthest fixture.
  2. Pump runs under the same on/off logic as the dedicated mode.
  3. Select the pump size for the pressure loss across the crossover valve and DHW system.
  4. Insulate the hot water and return lines to reduce heat loss; Rinnai strongly recommends this.
  5. Pump connects to the T/T4 terminal on the PC board.

Applies to: I-Series Plus Condensing Combi Boiler, crossover mode piping

Models

IP120199CNIP150199CN

More Rinnai boiler sequences

Take it to the job

Sequences of operation, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 104. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.