Daikin · Heat pump · Startup
Five-step commissioning set-up
What happens, in order
- On the welcome screen, select Unitary (default) before going to the set-up screen.
- Tap Begin set-up to start the commissioning process.
- Complete Step 1, Communication connect to the home Wi-Fi network and let the thermostat check and update its software.
- Complete Step 2, Personalization set language, large font, date and time, thermostat name and degree units.
- Complete Step 3, Equipment Set-up confirm the equipment found or add or remove equipment, then configure cool, heat, heat pump, humidifier relay, aux alarm and heater kit settings.
- Complete System Optimization.
- Complete Preferences.
- Review all steps before finishing set-up so the system is configured properly and ready for the homeowner.
- Share the commissioning report with the homeowner and the dealer before closing the job.
Applies to: Daikin One Touch smart thermostat, commissioning
More Daikin heat pump sequences
- 3-minute standby before restart · Startup
- Commissioning and test run · Startup
- Preheating control before inverter start (open phase) · Startup
- System start-up procedure with evacuation and checks · Startup
- Triple evacuation method (recommended) · Pump/purge
- 3-D airflow auto-swing order · Other
- Commissioning sequence in the app · Other
- Compressor frequency control priority · Other
Related
Take it to the job
Sequences of operation, error codes and tips work offline in the HVACopedia app.
Source: Daikin One Touch installation training TRC-10, p. 32, 35-36. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.