Navien · Boiler troubleshooting

Wiring zone pumps with domestic hot water (DHW) recirculation

NCB700

What is going on

The NCB700 can run 3 zone pumps and DHW recirculation together. Recirculation can be set to a timer, aquastat or HotButton input, or the boiler can control it through the DHW Recirculation menu.

Check in this order

  1. Wire the zone pumps and thermostats as in the zone pump diagram.
  2. Connect the recirculation pump (max 2.5 A) to its terminal with line and neutral.
  3. Connect the recirculation timer, aquastat or HotButton push button if the Recirculation menu is set to External Recirculation.
  4. If the DHW Recirculation menu is set to Always On, Intelligent or Weekly, no extra aquastat or HotButton is needed.
  5. If using Mixed Preheat, no recirculation pump is needed; select Mixed Preheat in the DHW Recirculation menu.
  6. If using External Recirculation, install a recirculation pump and select External Recirculation in the DHW Recirculation menu.

Applies to: NCB700 boilers with zone pumps and DHW recirculation

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NCB700 installation and operation manual, p. 211. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.