Navien · Boiler troubleshooting
Adjust gas/air ratio with digital manometer
What is going on
Alternate method to check the gas/air ratio when no analyzer is available.
Check in this order
- Connect the digital pressure manometer to the port as shown in the manual (Figure 8). Use the positive side of a dual port manometer.
- Activate multiple zones and set the boiler to the required mode.
- Compare the reading with the value in the pressure table (-0.02 in ±0.01 in for propane).
- If the value is out of range, locate the set screw and turn it no more than 1/4 turn clockwise to adjust the gas valve.
- Use a 5/32 in or 4 mm Allen wrench. Remove the screw-on cap to reach the set screw.
Applies to: Propane gas/air ratio check
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NFC-H propane and high altitude conversion guide, p. 2. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.