Wall mounting the boiler

NCB700

What is going on

Mount the upper bracket on studs, then hang the boiler and secure the bottom.

Check in this order

  1. Drill into studs and into drywall for plastic anchors; the bracket is pre-drilled at 16 in on center.
  2. Reinforce the wall if it is weak or framing is uneven.
  3. Fix the bracket level and confirm it can carry the boiler weight.
  4. Start one screw, check level, then install the other three.
  5. With help, lift the boiler above the bracket hooks and lower it onto them. Mounted this way, the back sits 5/8 in from the wall.
  6. Install two screws through the bottom bracket to secure the boiler.
  7. Leave clearance for service access.

Applies to: All NCB700 models

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NCB700 installation and operation manual, p. 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.