Navien · Boiler troubleshooting

Space heating does not work while DHW is running

CH-ASME

What is going on

The heating side stays off while the unit is heating domestic hot water.

Likely causes

  • Normal 3 minute standby when switching from DHW to heating
  • Pre-heating mode places the heating side on standby
  • Restricted filter on the heating side

Check in this order

  1. Wait about 3 minutes for the switch from DHW to heating to complete.
  2. Check whether the pre-heating icon is blinking on the remote controller.
  3. Clean the filters that belong to the heating side.

Applies to: Navien combination boiler, space heating

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien User's Operation Manual, p. 41. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.