Navien · Boiler troubleshooting

Refilling the space heating side with the auto feeder

CH

What is going on

The built-in automatic feeder fills the space heating side and stops on its own. Bleed air and check for leaks before restarting.

Check in this order

  1. Confirm the pump drain plug and DHW cold water inlet filter are installed and the drain fittings inside the unit are closed.
  2. Slowly open the water supply valve on the unit inlet, or open the supply at the water meter slowly if there is no valve.
  3. Check the unit for water leaks.
  4. Let the auto feeder fill the space heating side and stop.
  5. Check the manual air release to confirm the system filled properly.
  6. Bleed all air from the hot water lines, then close all hot water faucets.
  7. Turn power on to the unit.
  8. Open the gas valve.
  9. Open a hot water faucet to test. The unit should fire and run normally.

Applies to: CH combination boiler

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CH User's Operation Manual, p. 34. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.