Navien · Boiler troubleshooting
Preventing freeze damage
What is going on
Freeze protection needs electricity and runs whether the remote controller is ON or OFF. Direct vent installation reduces air movement inside the unit. Damage caused by freezing is not covered under warranty.
Likely causes
- Freezing temperatures or frequent power outages
- Negative pressure from backdrafting in the building
Check in this order
- Do not unplug the electrical supply cord.
- Insulate incoming and outgoing pipes.
- Do not shut off the gas valve.
- If the inlet pipe is frozen, thaw it with a hair dryer or heat gun until water flows.
- In a cold area with freezing temperatures or frequent outages, drain the unit to avoid damage.
Applies to: CH combination boiler
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CH User's Operation Manual, p. 39. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.