Navien · Boiler troubleshooting
Preparing and cleaning the heating piping
What is going on
Flush the whole heating circuit before connecting it to the boiler to remove debris, flux, solder, sediment and scale.
Likely causes
- Construction dust, copper burrs, sand or sludge left in the piping
- Old system with flux, grease or carbon residue
Check in this order
- Clean and flush the whole system before connecting piping to the boiler.
- On renovations, clean all circuit piping including radiators to remove sludge and deposits.
- Use cleaning products made for boiler systems. Use a stronger cleaner for heavy scale or sludge and follow its instructions.
- Use two wrenches when tightening pipe fittings onto the boiler, one to hold the connector and one to turn the fitting.
- Support the piping with its own hangers. Do not let the boiler or its accessories carry the pipe weight.
- Do not solder directly onto water connections; use threaded water fittings only.
- Failure to clean the system voids the warranty and can cause early heat exchanger failure.
Applies to: NCB700 heating circuit piping
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NCB700 installation manual, p. 182 and 184. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.