Navien · Boiler troubleshooting
No water at the hot water tap
What is going on
Hot tap opened but no water comes out.
Likely causes
- Shut-off valve on the hot or cold pipe is closed
- Cold water filter is clogged
- Unit is frozen
- Cross-plumbing between cold and hot lines
- Error code flashing on the remote controller
Check in this order
- Open the shut-off valves on the hot and cold pipes.
- Clean the cold water filter.
- Check the remote controller for a flashing error code and look it up in the error code guide.
- Check whether the unit is frozen.
- Check for cross-plumbing between the cold and hot water lines.
- Confirm the tap is open enough to draw at least 0.5 GPM through the unit.
Applies to: Navien combination boiler, domestic hot water
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien User's Operation Manual, p. 40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.