Navien · Boiler troubleshooting
No water at all when the hot water tap is opened
What is going on
Basic FAQ troubleshooting. The flow chart layout is hard to read, so the checks below are grouped by likely cause.
Likely causes
- Shut-off valve on hot or cold pipe closed
- Cold water inlet filter dirty
- Error code shown on remote controller
- Unit frozen
- Cross-plumbing between cold and hot lines
- Hot water fixture not open enough to draw at least 0.5 GPM through the boiler
Check in this order
- Make sure the shut-off valves on the hot and cold pipes are open.
- Check whether the cold water filter is clean.
- Check the remote controller for a flashing error code.
- Check whether the unit is frozen.
- Check for cross-plumbing between cold and hot water lines.
- Make sure the hot water fixture is open enough to draw at least 0.5 GPM through the boiler.
Applies to: CH combination boiler
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CH User's Operation Manual, p. 40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.