Measuring inlet gas pressure
What is going on
Procedure to measure the gas inlet pressure at the boiler under maximum firing. Only a licensed professional should do this.
Check in this order
- Close the manual gas valve in the supply line.
- Turn on the boiler. On the front panel, press the Back button and the Menu button together for 3 seconds, then turn the dial to select '7. Special Operations'.
- Press the dial to enter special operation mode.
- Turn the dial to select '7. SH 2nd MAX (CL 2e MAX)' and press the dial to select the mode.
- Press the Back button twice to return to normal operation.
- Run space heating so the gas in the supply line is purged.
- Let the boiler run until it shuts off from lack of gas, then turn the boiler off.
- Remove the 4 front cover screws (2 top, 2 bottom) with a Phillips screwdriver to access internal components.
- Loosen the screw shown in the manual and connect a manometer to the pressure tap on the outlet side. Zero the gauge before use.
- Reopen the manual gas valve and check for leaks.
- Open several domestic hot water taps at maximum temperature to bring the boiler to maximum firing rate.
- Run all other gas appliances in the house. At maximum firing, read the inlet pressure on the manometer.
- Compare the reading with the inlet pressure limits (see the gas pressure setting in this section).
Applies to: NCB700 gas pressure check
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NCB700 installation & operation manual, pp. 227-229. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.