Ignition, flame and power-loss protection
What is going on
If ignition fails, the boiler shuts off gas and flashes a 2-digit code on the room thermostat; see the troubleshooting section. If the flame drops out or re-ignition fails, gas is shut off and a code appears on the thermostat. After a power outage the boiler restarts on its own and needs no manual reset. Strong back-drafts in the flue are sensed by the air-ratio control module, which shuts off gas. Soft ignition limits noisy starts and backfires. Burner or heat exchanger overheating cuts gas and shows a code. Low water level in the heat exchanger shuts the unit down with a code, and a level sensor triggers the automatic water refill.
Check in this order
- Read the flashing 2-digit code on the room thermostat and find it in the error code guide.
- For a flame, ignition or back-draft lockout, check the venting and the gas supply before restarting.
- For a low-water shutdown, confirm the system pressure and that the auto feeder is working.
Applies to: Combination boiler safety functions 1 to 8
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CH ASME User's Operation Manual, p. 8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.