Hot water scald risk and DHW temperature setting

NCB700

What is going on

Domestic hot water temperature above 52 °C (125 °F) can cause instant severe burns or death. The factory setting is 49 °C (120 °F). Children, disabled and elderly people are most at risk.

Check in this order

  1. Check the water temperature before use on children, elderly or disabled people.
  2. Use the lowest DHW setting that gives comfortable hot water.
  3. If temperatures above 52 °C (125 °F) are needed, install a thermostatic mixing valve or temperature limiting valve.
  4. Check local codes for maximum permitted water temperature in care homes, schools and similar sites.
  5. Read the manual fully before changing the temperature setting.

Applies to: All NCB700 models

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: navien_ncb700-installation-and-operation-manual.pdf, p. 166 and p. 167. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.