Gas type, propane and high altitude conversion
What is going on
The boiler leaves the factory set for natural gas. Propane or high altitude operation needs the Navien propane and high altitude conversion kit. Field conversion without the kit is not allowed and voids the warranty.
Likely causes
- Boiler gas type does not match the supply gas
- Installation at high altitude
Check in this order
- Check the rating plate for gas type, gas pressure, water pressure and electrical supply before installing.
- Do not install the boiler if these do not match the site. Wrong gas type causes abnormal combustion.
- Use only the Navien propane and high altitude conversion kit for any propane conversion.
- Remove the front cover to reach the conversion kit inside the cabinet.
- Only a licensed professional should connect the gas supply.
- Test the appliance and all gas connections for leaks before operating.
Applies to: NCB700 boilers, gas conversion
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NCB700 installation manual, p. 176. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.