Navien · Boiler troubleshooting

External recirculation with NaviCirc

NCB700

What is going on

DHW recirculation loop using a NaviCirc valve on the faucet furthest from the boiler and a recirculation pump.

Check in this order

  1. Select the Intelligent or Weekly option in the external recirculation DHW menu for best performance.
  2. To use aquastat control, install an aquastat on the DHW line and connect it to terminal CNC6 on the PCB.
  3. Install the NaviCirc recirculation valve on the faucet furthest from the boiler.
  4. Use a recommended recirculation pump (see the pump setting table on this page).
  5. Keep the recirculation pipe within the maximum length table.

Applies to: NCB700 DHW recirculation

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NCB700 installation and operation manual, p. 35. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.