Navien · Boiler troubleshooting

Draining the combination boiler

CH

What is going on

Have a bucket ready to catch water. The manual's figure shows the drain points, and the text reads some drain fittings as "coke" (likely cock or valve).

Check in this order

  1. Turn off power to the unit.
  2. Close the gas valve.
  3. Close the water supply valve on the unit inlet. If there is no valve, shut off the supply at the water meter.
  4. Open the pump drain on the pump and let the water drain.
  5. Open the pump drain at the hot outlet side, open the drain valves inside the unit, open the drain valve at the pump, and remove the filter from the cold inlet side.
  6. When fully drained, refit the pump drain plug and inlet filter and close the drain fittings inside the unit.

Applies to: CH combination boiler

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CH User's Operation Manual, p. 33. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.