Choosing the installation location

NCB700

What is going on

Pick a site that has room for the boiler, proper venting, a condensate drain, and access to gas, water and power. Do not install outdoors, in an RV or in any mobile vehicle.

Likely causes

  • Site lacks a drain for condensate
  • Site is humid, dusty or has corrosive chemicals in the air

Check in this order

  1. Do not install the boiler outdoors or in a vehicle; carbon monoxide risk and warranty is not covered.
  2. Confirm at least one carbon monoxide detector is installed in the living space before commissioning.
  3. Locate the boiler near the building water, gas and electrical entries.
  4. Avoid excessively humid areas and keep the gas ignition parts protected from dripping or spraying water, including during service.
  5. Keep combustible materials and laundry away from the boiler and its vent.
  6. Do not install where hairspray, aerosol detergents, chlorine or similar chemicals are used.
  7. Do not install where gasoline or other flammable products are used or stored.
  8. Do not install on carpet.
  9. Keep the room ambient temperature above 0 °C (32 °F) and below 49 °C (120 °F).
  10. Install a suitable drain pan under the boiler if no drain is available, and make sure it does not block combustion air.

Applies to: NCB700 indoor installation

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NCB700 installation manual, p. 177-179. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.