Navien · Boiler troubleshooting

Choosing an installation location

NCB700

What is going on

Location checks before mounting the boiler indoors.

Check in this order

  1. Do not install outdoors or in an RV, trailer, boat or other moving vehicle.
  2. Confirm at least one carbon monoxide detector is in the living space before start-up.
  3. Install where a condensate drain is available and leaks will not damage the area.
  4. Keep the boiler away from dust, hair spray, chlorine and other chemical fumes and flammables.
  5. Keep the ambient temperature above 32°F (0°C) and below 120°F (49°C).
  6. Keep the gas ignition components protected from dripping or spraying water.
  7. Do not install in bathrooms, bedrooms, or closed or poorly ventilated rooms.

Applies to: Indoor installations

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NCB700 installation and operation manual, p. 14. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.