Navien · Boiler troubleshooting

Assembling the common vent collar kit on the boiler

NCB700

What is going on

Fit the common vent collar kit to the boiler exhaust before running a common vent.

Check in this order

  1. Remove the screws holding the exhaust vent adapter.
  2. Open the front cover and pull the exhaust vent adapter off the top of the unit.
  3. Disconnect the VID (Vent Installation Detector) wiring from the harness.
  4. Fit the common vent collar kit onto the boiler exhaust duct.
  5. Use the collar's maintenance port to check the damper plate. Full inspection steps are in section 9.9.

Applies to: NCB700-190/060, NCB700-190/080, NCB700-240/110, NCB700-240/130, NCB700-250/150

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NCB700 installation and operation manual, p. 96. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.