Rheem · Heat pump

c First-stage cooling

Normal status Rheem/Ruud PRL-JEC heat pump (Comfort Control2 ICC)

What the display is showing

Lowercase c steady on the display: first-stage cooling was requested and the compressor is running. Normal. The red Y1 LED is lit at the same time. A flashing c is the anti-short-cycle / minimum-run timer (separate row).

Applies to: Rheem/Ruud PRL-JEC heat pumps with Comfort Control2 ICC

Settings for these units

Outdoor unit clearances · Rheem/Ruud PRL-JEC heat pump (Comfort Control2 ICC)

LocationMinimum
Above unit (fan discharge)60 in. [1524 mm]
Coil air inlets (3 sides)6 in. [152 mm]
Service access side24 in. [610 mm]
Between two units (grille sides aligned)12 in. total (6 in. per unit)

Do not reduce the 60 in. discharge or 24 in. service clearances.

Inlet clearances under 6 in. reduce capacity and efficiency.

Models that show this code

4 models in Rheem/Ruud PRL-JEC heat pump (Comfort Control2 ICC)

RPRL-024JECRPRL-036JECRPRL-048JECRPRL-060JEC

Other codes on the same units

Sequence of operation

What the unit does around this code, step by step.

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rheem PRL-JEC Installation Instructions, Comfort Control2 section 12.3 and 12.6, pp.19-25. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.