Noritz tankless water heater error codes
46 codes (20 faults, 26 normal display and menu codes), plus 3 settings tables.
| Code | Meaning | Severity / type |
|---|---|---|
| 06 | Low recirculation flow (warning only) | Low |
| 10 | Abnormal combustion (NRCR, gas supply related) | High |
| 11 | Ignition failure (no flame detected) | High |
| 12 | Flame loss (repeated) | High |
| 14 | Thermal fuse failure | High |
| 16 | Abnormally high outlet temperature | High |
| 20 | High limit switch tripped | High |
| 29 | Condensate collector water level abnormal | Medium |
| 061 | Recirculation abnormality (sub-code of 06) | Low |
| 062 | Recirculation abnormality (sub-code of 06) | Low |
| 63 | Recirculation abnormality (no recirculation flow) | Medium |
| 65 | Main water control servo abnormality | Medium |
| 66 | Bypass water control servo abnormality | Medium |
| 73 | Circuit board setting abnormality | Low |
| 90 | Combustion abnormality | High |
| 91 | Gas conversion not done correctly | Critical |
| 901 | Combustion abnormality (sub-code of 90) | High |
| 902 | Combustion abnormality (sub-code of 90) | High |
| C1# | Descaling reminder (C11-C19) | Low |
| F76 | Multi-system communication error | Low |
| MM14 | Maintenance monitor 14 - flow rate | Menu / mode display |
| MM30 | Maintenance monitor 30 - inlet water temperature | Menu / mode display |
| MM31 | Maintenance monitor 31 - outlet water temperature | Menu / mode display |
| MM32 | Maintenance monitor 32 - heat exchanger water temperature | Menu / mode display |
| MM49 | Maintenance monitor 49 - fan speed | Menu / mode display |
| MM86 | Maintenance monitor 86 - recirculation mode | Menu / mode display |
| BURNER ON indicator | Remote burner-on indicator | Normal status |
| Blue/Red backlight | Panel backlight colour | Normal status |
| Display window | Built-in display window (NRCR Pro) | Menu / mode display |
| Error History | Error history list | Menu / mode display |
| Flame | Burner heating (flame symbol) | Normal status |
| Flush Mode | Descaling (flush) mode | Menu / mode display |
| Freeze Prevention | Freeze prevention running | Normal status |
| GPM | Hot water flow rate readout | Normal status |
| Heater Info. | Heater information screen | Menu / mode display |
| High Temp | High temperature setting | Normal status |
| LP | Propane (LP) gas type | Normal status |
| Locked | Operation panel locked | Normal status |
| Maintenance Monitor | Maintenance Monitor menu | Menu / mode display |
| POWER indicator | Remote power indicator | Normal status |
| PRIORITY indicator | Remote priority indicator | Normal status |
| Recirc | Recirculation pump running | Normal status |
| Sys. Maint. Monitor | System maintenance monitor (multi-unit) | Menu / mode display |
| Timer | Recirculation timer active | Normal status |
| Trial Operation | Trial operation of parts (EZ Start Plus) | Menu / mode display |
| Vacation | Vacation mode active | Normal status |
Settings and specs
Indoor clearances (required and recommended)
Clearances · Noritz NRCR
| Location | Required | Recommended (service) |
|---|---|---|
| Top | 12 in. (300 mm) | 3 in. (76 mm) above and below exhaust |
| Front | 4 in. (100 mm) | 24 in. (610 mm) |
| Sides | 3 in. (76 mm) | 8 in. (203 mm) |
- Required clearances apply to both combustible and non-combustible materials.
- Recommended space is for service and quick access to gas and water shut-offs.
- Near a kitchen range with indoor air supply, fit a non-combustible dividing plate wider than the heater.
Source: Noritz NRCR Pro training (NRCR92/NRCR111, Printable V3), Installation clearances, p.18
Water quality limits
Specifications · Noritz EZ, Noritz NRCR
| Contaminant | Max allowed |
|---|---|
| Total hardness | 200 mg/L (12 gpg) |
| Aluminum | 0.05 to 0.2 mg/L |
| Chloride | 250 mg/L |
| Copper | 1.0 mg/L |
| Iron | 0.3 mg/L |
| Manganese | 0.05 mg/L |
| pH | 6.5-8.5 |
| Total dissolved solids | 500 mg/L |
| Zinc | 5 mg/L |
| Sulfate | 250 mg/L |
| Residual chlorine | 4 mg/L |
- Damage from water above these levels, or from ignoring a C1# descaling reminder, is not covered by warranty.
- Hardness and residual chlorine limits are Noritz suggestions; the rest are EPA secondary standards.
Source: Noritz EZ/NRCR Owner's Guide (Rev. 10-25), Water quality and maintenance, p.28
Models covered
EZ111DVEZ71DVEZ98DVN-0841MCN-0841MC-DVN-0842MCN-0842MC-DVNCC199-DVNCC199-SVNCC199CDVNRC111-DVNRC111-SVNRCR111DVNRCR92DV
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.