Navien · Tankless water heater troubleshooting
Recovering a possibly frozen water heater
What is going on
Thaw steps when hot water will not flow and freezing is suspected.
Likely causes
- Freezing from back drafting or loss of power or gas
Check in this order
- Press the Power button to turn off the unit.
- Close the gas valve.
- Open the hot water faucet closest to the unit.
- Use a hair dryer or portable electric heater to warm both the primary and secondary heat exchangers.
Applies to: NPN indoor and outdoor models
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPN user's information manual, p. 20. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.