Navien · Tankless water heater troubleshooting

E109 fan motor fault on NHW700

Navien NHW700

What is going on

The fan speed signal stays near 0 or too low. Shows after 3 seconds of low speed while firing.

Likely causes

  • Fan seized or loose
  • No power to the fan
  • Wet fan connector (from a leak)
  • Loose fan plug at the PCB
  • Failed fan motor
  • PCB fault

Check in this order

  1. Power off before unplugging connectors or measuring resistance.
  2. Spin the fan by hand. Will not turn: replace the fan motor.
  3. Check the fan plug at the fan and at the PCB. Wet plug: power off, dry everything, put it back.
  4. Power on and check the fan supply red-black about 127-184 V DC (about 170 V), black-yellow 15 V DC. Speed control black-orange 0-7.5 V DC, speed pulse black-white.
  5. No supply voltage check the plug, then the PCB.
  6. Supply good, fan slow check the APS, cycle power fully. Code comes back: replace the fan motor.
  7. New fan and still there replace the PCB.

Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.7 p.102-103, 5.2 p.71, 5.5 p.74. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.