Navien · Tankless water heater troubleshooting
E109 fan motor fault on NHW700
What is going on
The fan speed signal stays near 0 or too low. Shows after 3 seconds of low speed while firing.
Likely causes
- Fan seized or loose
- No power to the fan
- Wet fan connector (from a leak)
- Loose fan plug at the PCB
- Failed fan motor
- PCB fault
Check in this order
- Power off before unplugging connectors or measuring resistance.
- Spin the fan by hand. Will not turn: replace the fan motor.
- Check the fan plug at the fan and at the PCB. Wet plug: power off, dry everything, put it back.
- Power on and check the fan supply red-black about 127-184 V DC (about 170 V), black-yellow 15 V DC. Speed control black-orange 0-7.5 V DC, speed pulse black-white.
- No supply voltage check the plug, then the PCB.
- Supply good, fan slow check the APS, cycle power fully. Code comes back: replace the fan motor.
- New fan and still there replace the PCB.
Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.7 p.102-103, 5.2 p.71, 5.5 p.74. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.