Navien · Tankless water heater troubleshooting
E004 false flame on NHW700
What is going on
Flame signal seen for 3 seconds before the burner should light, or for 3 seconds during post-purge after gas was shut off. The fan purges and the pump runs. Auto reset.
Likely causes
- Gas valve leaking through (flame before or after a burn)
- Spark jumping from electrode to flame rod
- Gas pressure above range pushing the valve open
- Bad ground or electrical noise
- PCB fault
Check in this order
- Gas unit only a qualified gas technician should work on it. Power off at the switch before unplugging any connector.
- Watch the burner with no call for heat. Flame there with no ignition: the gas valve is leaking, replace it.
- No real flame it is electrical noise. Check the ground wire and the flame rod position. Clean or replace the flame rod.
- Check the spark is going to the burner, not to the flame rod.
- Check inlet gas pressure is not above range (natural gas max 10.5 in. WC, propane max 13 in. WC).
- Still there replace the PCB.
Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.2 p.97, 3.3.2 p.28. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.