Navien · Tankless water heater troubleshooting
E003 ignition failure on NHW700: full check
What is going on
The heater tries to light 10 times. If it never sees flame it shows E003 and locks out (manual reset).
Likely causes
- Gas valve off or low inlet gas pressure
- Gas line or CSST too small or crushed by an over-tightened nut
- Gas meter too small for all appliances
- Electrode gap wrong, cracked insulator or spark jumping to the burner
- No power to the ignition transformer or bad transformer
- Gas valve or manifold solenoid not opening
- Dirty or bent flame rod, bad ground
- APS hose broken or blocked, bad APS
- Wrong DIP switch or gas type setting, blocked flue
- PCB fault
Check in this order
- Gas unit only a qualified gas technician should work on it. Power off at the switch before unplugging any connector.
- Make sure the gas valve is open. Measure inlet gas pressure with a manometer, static and with the heater and other gas appliances firing. Range: natural gas 3.5-10.5 in. WC, propane 8.0-13 in. WC.
- Check the gas pipe size and any CSST fitting that may be over-tightened. Check the meter size.
- Watch for spark. No spark: pull the electrode, look for a cracked insulator and the insulating gasket. Gap to burner should be 3-4 mm.
- Check voltage to the igniter (blue-brown): about 96-138 V AC while it is trying to light. Voltage there but no spark: replace the ignition transformer. No voltage: replace the PCB. Check the boots on the spark wires.
- Check voltage to the gas valve while lighting: 135-195 V DC on each valve wire (black P1 to yellow, blue, red, brown, white). Voltage there but the valve does not open: replace the gas control valve. Check the manifold solenoids too.
- Check the flame rod, its wire and connector CNI1 #1, and the ground. Flame current should read 0-15 uA while the burner runs. Clean or replace the flame rod.
- Check the APS hose and APS, the DIP switches and gas type, the manifold and the flue.
- Repeated light-then-go-out look at flame position and burner for debris, check the ground and manifold solenoids.
- Everything checks good and it still fails: replace the PCB.
Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.1 p.92-96, 5.5 p.75, 3.3.2 p.28. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.