Navien · Tankless water heater troubleshooting

NaviCirc: leak, poor operation or noise right after install

Navien NaviCirc

What is going on

Most problems right after a NaviCirc install come from the hose connections, air left in the lines, or the valve being forced against the wall.

Likely causes

  • Teflon tape or sealant used on the 1/2 in male ports, or hoses without rubber gaskets
  • Air purge too short
  • Valve mounted crooked or anchors over-tightened
  • Shutoff valves left closed

Check in this order

  1. Warning both hot and cold shutoff valves must be open whenever the NaviCirc is in use. Running it with the valves closed builds hot water pressure and can hurt someone.
  2. Leak close the shutoff valves first, then fix the connection. Do not use Teflon tape or adhesive on the NaviCirc 1/2 in male ports. Use hoses with rubber gaskets.
  3. Hose layout faucet hoses go to HOT OUT / COLD OUT, the supply hoses from the shutoff valves go to HOT IN / COLD IN (3/8 to 1/2 in adapters as needed).
  4. Purge air open both hot and cold faucets and let them run long enough to clear all air. A short purge can stop the valve from working and air can damage the pump.
  5. Mounting it must sit level (horizontal) and be fixed with the 3 supplied anchors. Do not crank the anchors down hard, it can damage the valve.
  6. Limits max 150 psi, water 41-180 F, indoor only, room 32-122 F.

Applies to: NaviCirc recirculation valve (PFFW-SXX-001) on Navien NPE-A/A2/S2, NPN water heaters and NCB-H/NFC-H combi boilers

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NaviCirc Installation and Operation Manual (navicirc-installation-and-operation-manual-en.pdf), p.6, 9-13. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.