Navien · Tankless water heater troubleshooting

Hot water is cold or turns cold

NPE

What is going on

Hot water faucet runs cold or goes cold and stays cold.

Likely causes

  • Clogged cold water inlet filter
  • Hot water faucet not open far enough (less than 2 LPM through the heater)
  • Error code on front panel
  • Missing check valve on external recirculation return line

Check in this order

  1. Clean the cold water inlet filter (see the Operation manual, section 4.4).
  2. Open the hot water faucet fully and confirm at least 2 LPM flows through the heater.
  3. Check the front panel for an error code and refer to the Error Code Guide.
  4. If an external recirculation system is installed, confirm a check valve is on the return line.

Applies to: NPE water heaters

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPE remote controller manual, p. 29. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.