Navien · Tankless water heater troubleshooting
Hot water is cold or turns cold and stays cold
What is going on
Water from the hot tap stays cold or goes cold during use.
Likely causes
- Cold water inlet filter is clogged
- Hot tap flow is too low (less than about 0.5 GPM)
- An error code is showing
- Check valve missing on external recirculation return line
Check in this order
- Clean the cold water inlet filter (page 19).
- Open the hot water faucet completely.
- Check for an error code and look it up on page 22.
- If an external recirculation system is installed, make sure there is a check valve on the return line.
Applies to: NPN indoor and outdoor models
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPN user's information manual, p. 21. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.