Navien · Tankless water heater troubleshooting

Flushing the heat exchanger

NPN

What is going on

Circulate cleaning solution through the heat exchanger using a flushing kit and circulation pump.

Check in this order

  1. Gather a bucket of 5 gallons or larger, cleaning solution diluted with water, three hoses, a water circulation pump and a flushing kit.
  2. Press the Power button to turn off the unit, then disconnect its power supply.
  3. Close the hot and cold water line valves labeled C and D.
  4. Connect one tube to valve A and place the free end in the bucket.
  5. Connect a tube from the circulation pump outlet to the cold water line at valve B.
  6. Connect a tube from the circulation pump inlet and place the free end in the bucket.
  7. Pour the cleaning solution into the bucket.
  8. Open valves A and B.
  9. Run the pump for at least 45 minutes.
  10. Close valve B and open valve D, let water flow for 5 minutes, then close A and open C.
  11. Disconnect all tubes.
  12. Remove the cold water inlet filter, clean out residue, and reinstall it with the cap securely tightened.
  13. Reconnect power and press the Power button to turn the unit on.

Applies to: NPN indoor and outdoor models

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPN user's information manual, p. 17-18. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.