Navien · Tankless water heater troubleshooting
Flushing the heat exchanger
What is going on
Circulate cleaning solution through the heat exchanger using a flushing kit and circulation pump.
Check in this order
- Gather a bucket of 5 gallons or larger, cleaning solution diluted with water, three hoses, a water circulation pump and a flushing kit.
- Press the Power button to turn off the unit, then disconnect its power supply.
- Close the hot and cold water line valves labeled C and D.
- Connect one tube to valve A and place the free end in the bucket.
- Connect a tube from the circulation pump outlet to the cold water line at valve B.
- Connect a tube from the circulation pump inlet and place the free end in the bucket.
- Pour the cleaning solution into the bucket.
- Open valves A and B.
- Run the pump for at least 45 minutes.
- Close valve B and open valve D, let water flow for 5 minutes, then close A and open C.
- Disconnect all tubes.
- Remove the cold water inlet filter, clean out residue, and reinstall it with the cap securely tightened.
- Reconnect power and press the Power button to turn the unit on.
Applies to: NPN indoor and outdoor models
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPN user's information manual, p. 17-18. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.