Navien · Tankless water heater troubleshooting

E517 / E773 DIP switch and gas type on NHW700

Navien NHW700

What is going on

E517: the PCB DIP switches are set wrong (manual reset). E773: the heater thinks the gas connected does not match the gas type set at install (reset by parameter).

Likely causes

  • Capacity DIP switches (DIP 2) do not match the model
  • Panel DIP 1-1 gas type set wrong
  • Wrong gas connected or manifold not changed during LP conversion
  • Measuring tolerance (E773 can show with the right gas)

Check in this order

  1. Gas unit only a qualified gas technician should work on it. Power off at the switch before unplugging any connector.
  2. E517 set the PCB DIP switches to match the model and reset. Still there: replace the PCB.
  3. E773 check what gas is connected. Panel DIP 1-1 ON = propane, OFF = natural gas.
  4. Check the manifold nozzle size matches the gas and look at the flame (right number of flames in each row). Check for gas leaks.
  5. The unit can only be converted with the Navien conversion kit.
  6. Gas and settings match but E773 stays call Navien technical support.

Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.16 p.111, 7.2 p.91, 5.12 p.82-84, 5.10 p.80, 3.3 p.24. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.