Navien · Tankless water heater troubleshooting

E434 flow regulating valve fault on NHW700

Navien NHW700

What is going on

No feedback from the flow regulating (water adjustment) valve for over 10 seconds while it is fully open. Sub code 1 = open, 2 = close. Alarm only.

Likely causes

  • Loose valve plug
  • Valve stuck or failed
  • No supply from the PCB

Check in this order

  1. Power off before unplugging connectors or measuring resistance.
  2. Cycle power to the heater.
  3. Reseat the valve plug.
  4. Check supply 12 V DC blue P3-P1 and P6-P1. Position signal blue P2-P1 0-5 V DC changes as the valve moves. Drive pulses on P4, P5, P7, P8.
  5. Supply good but valve does not move or reads wrong: replace the valve (measure its resistance first).
  6. No supply replace the PCB.

Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.13 p.108, 7.2 p.91, 5.5 p.74. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.