E407 / E421 / E441 thermistor codes on NHW700
What is going on
On the NHW700: E407 = hot water outlet thermistor, E421 = direct water thermistor, E441 = heat exchanger outlet thermistor. Sub code 1 = open, 2 = shorted. Auto reset. Note: E421 and E441 mean different sensors on the NPE-2.
Likely causes
- Broken or unplugged thermistor wire
- Shorted wiring
- Failed thermistor
- PCB fault
Check in this order
- Power off before unplugging connectors or measuring resistance.
- Read the sub code (1 open, 2 short) in the error history.
- Check the wire and plug of that sensor. Reconnect it.
- Measure the sensor resistance with the sensor cool. Bad reading or broken wire: replace the thermistor.
- Find and repair any shorted wiring.
- With power on, the sensor signal at the PCB should be 0-5 V DC and change with temperature (inlet P13-P14, outlet 2 P11-P12, outlet 1 P9-P10).
- Sensor good and code stays replace the PCB.
Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.1 p.88, 7.3.11-7.3.14 p.106-109, 5.7 p.77, 5.5 p.75. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.