Trane · General troubleshooting

XR724 says heating or cooling but no air at the registers

Trane XR724

What is going on

The display shows Heating or Cooling but no air comes out of the vents.

Likely causes

  • Blower on-delay has not finished
  • Equipment problem (blower, board, wiring)

Check in this order

  1. Wait one minute for the blower on-delay to finish, then check the registers again.
  2. Still no air check the blower and board at the indoor unit. Use Test Mode > Blower to energize G (and BK at 50 % or 100 % on variable speed) and see if the blower runs.
  3. On a variable speed indoor unit, check how BK is wired. The wiring diagrams in this guide say to cut the factory BK jumper at the indoor unit when BK is run from the XR724.

Applies to: Trane XR724 touchscreen comfort control TCONT724AS42DA (also sold under American Standard)

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane XR724 Comfort Control (TCONT724AS42DA) User Guide and Installer's Guide 18-HD82D1-1E-EN, Troubleshooting p.38 and Test Mode p.8, Field Wiring Diagrams p.20-36. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.