Trane · General troubleshooting
Room goes past setpoint in heating (XR724)
What is going on
The house heats above the heat setpoint before the system stops. Normal when the minimum on time for the compressor or indoor heat is still running.
Likely causes
- Minimum on time for the compressor or the indoor heat has not run out
Check in this order
- Confirm the overshoot is small and stops once the minimum run time ends. That is normal operation.
- If the customer does not like it, change Control Response under Installer Settings > Comfort Settings (Normal, Less Aggressive, More Aggressive).
Applies to: Trane XR724 touchscreen comfort control TCONT724AS42DA (also sold under American Standard)
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane XR724 Comfort Control (TCONT724AS42DA) User Guide and Installer's Guide 18-HD82D1-1E-EN, Troubleshooting p.38 and Control Response Profiles p.9. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.