Trane · General troubleshooting

Fan runs all the time (XR724)

Trane XR724

What is going on

The indoor blower never shuts off.

Likely causes

  • Fan mode set to On or Circ
  • Equipment problem (stuck relay, board or wiring keeping G on)

Check in this order

  1. Check the fan mode. On or Circ keeps the blower running on purpose. Set it to Auto if the customer does not want that.
  2. Fan on Auto and still running check for G being powered without a call (shorted wire) or a fault at the indoor board.

Applies to: Trane XR724 touchscreen comfort control TCONT724AS42DA (also sold under American Standard)

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane XR724 Comfort Control (TCONT724AS42DA) User Guide and Installer's Guide 18-HD82D1-1E-EN, Troubleshooting p.38. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.